Prediction: immobilised lactase will keep a higher activity than free lactase at higher temperatures, because the alginate holds the enzyme and reduces denaturation.
Preparing the enzyme: mix lactase solution with sodium alginate solution and drip it from a syringe into calcium chloride solution to form beads; rinse the beads with distilled water. For the free enzyme, dilute the same volume of the same lactase solution with water, so both forms contain the same quantity of enzyme.
Independent variable: temperature — thermostatically controlled water baths at 30, 40, 50, 60 and 70 °C, tested for each form of the enzyme. Leave the lactose solution and enzyme in the bath for 5 minutes before mixing.
Dependent variable: after exactly 10 minutes, remove the beads by pouring through a sieve (for the free enzyme, test a sample immediately) and dip a glucose test strip into the solution, comparing its colour with the chart to find the glucose concentration. Benedict's test cannot be used because lactose itself is a reducing sugar.
Standardised variables: same volume and concentration of lactose solution (e.g. 20 cm³ of 5%), same pH using a buffer, same incubation time.
Control: beads made with sodium alginate but no lactase, placed in lactose solution at each temperature, to show that the glucose comes from the enzyme and not from the alginate or the lactose solution.
Reliability: three replicates for each form at each temperature; calculate a mean glucose concentration.
Risk: water baths at 60–70 °C can scald — handle tubes with a holder; calcium chloride is an irritant — wear eye protection. Overall risk is low.